| XeVision component or item |
specifications |
figure #
|
remarks |
| ballast XV1-14 / XV1-28 |
|
|
|
| The ballast comes either in 12 VDC (XV1-14) or 24 VDC (XV1-28) |
|
|
|
| The ballast has to be used in combination with D1S bulbs |
|
|
|
|
Operating temperature: -40 C + 85 C |
|
|
|
Storage temperature: -40 C +100 C |
|
|
|
Weight: 400 gr |
|
|
|
Dimensions (mm) |
fig. 1
|
Dimensions |
| compliances: |
|
|
|
| The ballast is encased in a Al metal box and fully potted in epoxy. The connectors are sealed with a silicone seal. Therefore the ballast has very good humidity resistance characteristics. |
Seal integrity according to IP 54 |
|
|
| If a shielded cable will be used between the ballast and the lamp (we offer this for an additional fee), it will be class 5 |
EMC complies to CISPR-25 class 3 |
|
|
| These are not MIL specs, but the highest automotive standards (which are possibly higher than aviation standards) including EMI/RFI. This cable length should be less then 3 ft as delivered with the kit. The existing wiring in the a/c can be used and connected to the pigtail provided. No shielding is necessary for the power supply wires. |
|
|
|
|
The maximum impedance of the lead wire from the battery or power supply to the ballast is 50 milli-Ohms including CB and connector resistance. |
|
|
|
To assure proper starting characteristics, the maximum distance between the ballast and the D1S bulb is 3 m (9 feet). Note: EMC may vary with different cable length. For optimum performance the shortest possible cable length is highly recommended. |
|
|
| Ballast input/output connectors: |
|
fig. 2
|
ballast input connectors |
| Supply voltage ratings (VDC): |
|
|
|
| Nominal voltage |
12 or 24 |
|
|
| Rated voltage |
12.8 or 26.4 |
|
|
| Operating voltage |
9 - 16 or 18 to 32 |
|
|
| Under lockout voltage |
< 6 or < 12 |
|
|
| Over lockout voltage |
>16 or >32 |
|
|
| Over voltage (1 min) |
24 or 36 |
|
|
| Reverse polarity protection |
yes |
|
|
|
|
|
|
| Supply current ratings (A): |
|
|
|
| (at ambient temp and rated supply V) |
|
|
|
|
0-5 msec: < 100 or < 100 |
|
|
|
up to 5 sec: <20 or < 20 |
|
|
|
in steady state: <4 or <2 |
|
|
| Circuit protection: |
|
|
|
|
20A or 10A slow blow fuse or CB must be added in series with the ballast to protect the circuit for any end of life conditions of the ballast |
fig. 3
|
circuit protection diagram |
| Output shutdown characteristics: |
|
|
|
|
The ballast operation is stopped within 1 second of an open circuit or short circuit occurs between the ballast and the D1S bulb. |
|
|
|
|
|
|
| D1S bulb/igniter |
|
|
|
| dimensions: |
see 3 view diagram |
fig 4.
|
D1S bulb 3 view and dimensions |
|
|
|
|
| Electrical: |
|
|
|
| type |
AMP Micro Quadlock code Vcontacts tin plates |
|
|
| pin definitions |
1 - Uocv |
|
|
|
2 - V battery/0v |
|
|
|
2 - + 550V |
|
|
| potentials |
Upin1-Upin2=1kV max |
|
|
|
|
|
|
| connector |
|
fig. 5
|
AMP connector |
|
|
|
|
| D1S Bulb data: |
|
|
|
| Technical data |
R99 |
|
|
| Test power at |
35 W +/- 0.3 W |
|
|
| Voltage |
84 V +/- 17 |
|
|
| Luminous flux |
3350 lm +/- 300 |
|
|
| Lumen maintenance |
1500 h 75% |
|
|
| Color X |
0.38 |
|
|
| Color Y |
0.385 |
|
|
| Color temperature, spectral radiant flux |
4200 K |
fig. 11
|
spectral radiant flux of D1S bulb |
|
|
|
|
| Starting characteristics: |
|
|
|
| Starting voltage max. |
23 kV |
|
|
| Starting current max. |
2.6 A |
|
|
| Wattage max. |
75.0 W |
|
|
| Run-up time max. |
1.3 s |
|
|
|
|
|
|
| Service life: |
|
|
|
| Tc> |
<3000 h |
|
|
| B3> |
>2000 h |
|
|
|
|
|
|
| Temperatures: |
|
|
|
| at pinch, max. |
400 C |
|
|
| at protection bulb |
700 C |
|
|
| at lamp base, max. |
240 C |
|
|
| at starter |
145 C |
|
|
|
|
|
|
| Xenon HID Plus: |
On top of the improved specification of the standard bulb the Plus D1S bulb offer an enhanced color stability and improved Lumen maintenance. In particular the enhanced color stability offers a top performance all over the lifetime of the bulb |
fig. 6
|
Color stability comparison |
|
|
fig 7
|
Lumen maintenance comparison |
|
|
|
|
|
|
|
|
| Standard cables |
|
|
|
| Operating temperature: |
range -40 C + 85 C |
|
|
|
|
|
|
| Current: |
Imax 7.5 A, Ipeak 30 A (300 sec) |
|
|
|
|
|
|
| Voltage: |
Dielectrical strength: 1000 V max |
|
|
|
|
|
|
| Two fixed cable lengths: |
|
fig. 8
|
cable assembly |
|
1035 mm |
|
|
|
535 mm |
|
|
|
|
|
|
| Custom cable length: |
max. 9 feet long (see above) |
|
|
|
|
|
|
| wire gauge: |
0.5 mm2 |
|
|
|
|
|
|
| Connectors: |
|
|
|
| AMP MQS at D1S bulb/igniter |
|
fig. 9
|
AMP connector |
| Yazaki (Haribara) at ballast |
|
fig 10
|
Yazaki Haribara connector |
|
|
|
|
| Placards and POH entries |
|
|
|